Ultra Seam US-150 Standing Seam Panel


US-200 | US-175LS | US-150 | US-150C | US-100CS | US- 200SB | US-100FP | US-150BP
The Ultra Seam standing seam system utilizes state of the art technology for roof integrity and positive weather-tightness. The Ultra Seam US-150 panel has been extensively tested in both steel and aluminum, and meets the stringent requirements of the “Standard Test Method for Structural Performance of SSMRS by Uniform Static Air Pressure Difference,” which has been adopted as ASTM E-1592. Seams require machine closing, by either hand or power seamers, both available on a job rental basis. The seaming process completely encloses and seals all clips and fasteners for the most watertight seal available. The US-150 panel, in addition to the standard 90-degree seam, can be double-locked to obtain a 180 degree architectural profile. The standing seam system is especially suitable where roof slopes are long and/or low, and unusually long panels are required. Available in various gauges of galvanized steel, galvalume, zincalume, aluminum, copper, zinc and stainless steel. Regardless of which material is selected, the optional stiffening ribs or striations are highly recommended in order to reduce the slight surface waviness of the metal known as “oil-canning.” Note: “oil-canning” is a natural phenomenon inherent in sheet metal products and therefore is not cause for rejection of the material.

Mechanical Seamer
Ultra Seam US-150 Panel
Clip Spacing Allowable Uniform Load
Material
Gauge
Panel
Width
Steel grade D
ASTM A653 (A446)
22
12"
22
16"
22
18"
Steel grade D
ASTM A653 (A446)
24
12"
24
16"
24
18"
Aluminum Alloy
3004 H34
.040
12"
.040
16"
Aluminum Alloy
3004 H34
.032
12"
.032
16"

24"

30"

36"

42"

48"

54"

60"
473
305
213
157
120
94
76
355
229
160
117
90
71
57
316
204
142
104
80
63
51
373
240
168
123
94
74
60
279
180
126
92
70
56
45
248
160
111
82
63
49
40
115
73
51
37
28
22
18
73
46
32
23
18
14
11
90
58
40
29
22
17
14
57
36
25
18
14
11
9
Table Provided for US-200 Panel General Reference Only. Loads are based on engineered calculations of the panel only. Allowable uniform load values based on three-span condition. For system requirements or design assistance please contact your nearest Ultra Seam representative.

Introduction | Profile | Details | Specification | Finishes | Retrofit | Projects | Plant Locations

last Up Dated: 10/27/01

©2001 Ultra Seam Incorporated
Questions: info@ultraseam.com