      Ultra Seam US-200 Standing Seam Panel


The Ultra Seam standing seam system utilizes state of the art technology for roof integrity and positive weather-tightness. The Ultra Seam US-200 panel has been extensively tested in both steel and aluminum, and meets the stringent requirements of the “Standard Test Method for Structural Performance of SSMRS by Uniform Static Air Pressure Difference,” which has been adopted as ASTM E-1592. Seams require machine closing, by either hand or power seamers, both available on a job rental basis. The seaming process completely encloses and seals all clips and fasteners for the most watertight seal available. The US-200 panel, in addition to the standard 90-degree seam, can be double-locked to obtain a 180 degree architectural profile. The standing seam system is especially suitable where roof slopes are long and/or low, and unusually long panels are required. Available in various gauges of galvanized steel, galvalume, zincalume, aluminum, copper, zinc and stainless steel. Regardless of which material is selected, the optional stiffening ribs or striations are highly recommended in order to reduce the slight surface waviness of the metal known as “oil-canning.” Note: “oil-canning” is a natural phenomenon inherent in sheet metal products and therefore is not cause for rejection of the material.

Mechanical Seamer


Ultra Seam US-200 Panel
Material
Gauge
Panel Width
Steel grade D ASTM A653(A446)
22
12''
22
16''
22
18''
Steel grade D ASTM A653 (A446)
24
12''
24
16''
24
18''
Aluminum Alloy
3004 H34
.040
12''
.040
16''
Aluminum Alloy
3004 H34
.032
12''
.032
16''
Clip Spacing Allowable
Uniform Load

24"

30"

36"

42"

48"

54"

60"
473 305 213 157 120 94 76
355 229 160 117 90 71 57
316 204 142 104 80 63 51
373 240 168 123 94 74 60
279 180 126 92 70 56 45
248 160 111 82 63 49 40
115 73 51 37 28 22 18
73 46 32 23 18 14 11
90 58 40 29 22 17 14
57 36 25 18 14 11 9

Table Provided for US-200 Panel General Reference Only.
Loads are based on engineered calculations of the panel only. Allowable uniform load values based on three-span condition. For system requirements or design assistance please contact your nearest Ultra Seam representative.